high contrast etdrs printed charts Search Results


86
Precision Vision high contrast etdrs printed charts
High Contrast Etdrs Printed Charts, supplied by Precision Vision, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/high+contrast+etdrs+printed+charts/pmc12386968-125-8-12?v=Precision+Vision
Average 86 stars, based on 1 article reviews
high contrast etdrs printed charts - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

90
CH Instruments chi-square test
Chi Square Test, supplied by CH Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/high+contrast+etdrs+printed+charts/pm31013506-64-3-12?v=CH+Instruments
Average 90 stars, based on 1 article reviews
chi-square test - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
EyeArt Laboratories eyeart v2.1
Prospective validation studies of AI in DR
Eyeart V2.1, supplied by EyeArt Laboratories, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/high+contrast+etdrs+printed+charts/pmc10164194-47-17-0?v=EyeArt+Laboratories
Average 90 stars, based on 1 article reviews
eyeart v2.1 - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
EMMES Corporation eva automated single letter (e-etdrs)
Effect of visual field loss on reading ability on <t>ETDRS</t> charts. (A) Microperimetry of the remaining central visual field in one eye with advanced choroideremia. The colored areas indicate the seeing parts of the retina. (B) ETDRS chart for measuring visual acuity. (C) A simulation of the appearance of the chart in B to the eye in A, making it difficult to track across the letters and obtain an accurate measure of visual acuity. (D) E-ETDRS presentation with single letter on the center of the screen. <t>(E)</t> <t>EVA-SL</t> presentation with a single line of letters across the center of the screen. (F) Simulation of visual field loss on EVA, the patient can more easily search around the letter as it stays within a limited area.
Eva Automated Single Letter (E Etdrs), supplied by EMMES Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/high+contrast+etdrs+printed+charts/pmc07316570-60-6-19?v=EMMES+Corporation
Average 90 stars, based on 1 article reviews
eva automated single letter (e-etdrs) - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
heidelberg engineering sd-oct
Effect of visual field loss on reading ability on <t>ETDRS</t> charts. (A) Microperimetry of the remaining central visual field in one eye with advanced choroideremia. The colored areas indicate the seeing parts of the retina. (B) ETDRS chart for measuring visual acuity. (C) A simulation of the appearance of the chart in B to the eye in A, making it difficult to track across the letters and obtain an accurate measure of visual acuity. (D) E-ETDRS presentation with single letter on the center of the screen. <t>(E)</t> <t>EVA-SL</t> presentation with a single line of letters across the center of the screen. (F) Simulation of visual field loss on EVA, the patient can more easily search around the letter as it stays within a limited area.
Sd Oct, supplied by heidelberg engineering, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/high+contrast+etdrs+printed+charts/pmc07306025-33-9-35?v=heidelberg+engineering
Average 90 stars, based on 1 article reviews
sd-oct - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
alcon inc etdrs chart by alcon
Objective grading of various reading charts with a surgical microscope. The reticule centers on the character being used for objective measurement: (A) 20/200 character on the <t>ETDRS</t> chart by <t>Alcon;</t> (B) 20/200 character on the ETDRS chart by Bausch & Lomb; (C) J16 character on the Rosenbaum chart; and (D - E) N24 characters on the alphabetical and numerical N-notation charts, respectively.
Etdrs Chart By Alcon, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/high+contrast+etdrs+printed+charts/pmc12135357-73-11-16?v=alcon+inc
Average 90 stars, based on 1 article reviews
etdrs chart by alcon - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Falkenstein Mikrosysteme GmbH etdrs
Objective grading of various reading charts with a surgical microscope. The reticule centers on the character being used for objective measurement: (A) 20/200 character on the <t>ETDRS</t> chart by <t>Alcon;</t> (B) 20/200 character on the ETDRS chart by Bausch & Lomb; (C) J16 character on the Rosenbaum chart; and (D - E) N24 characters on the alphabetical and numerical N-notation charts, respectively.
Etdrs, supplied by Falkenstein Mikrosysteme GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/high+contrast+etdrs+printed+charts/pm26318959-137-7-18?v=Falkenstein+Mikrosysteme+GmbH
Average 90 stars, based on 1 article reviews
etdrs - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
heidelberg engineering color fundus photography
Objective grading of various reading charts with a surgical microscope. The reticule centers on the character being used for objective measurement: (A) 20/200 character on the <t>ETDRS</t> chart by <t>Alcon;</t> (B) 20/200 character on the ETDRS chart by Bausch & Lomb; (C) J16 character on the Rosenbaum chart; and (D - E) N24 characters on the alphabetical and numerical N-notation charts, respectively.
Color Fundus Photography, supplied by heidelberg engineering, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/high+contrast+etdrs+printed+charts/pm39682518-56-20-36?v=heidelberg+engineering
Average 90 stars, based on 1 article reviews
color fundus photography - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
heidelberg engineering etdrs grid heyex 2 software
Illustration for 5 grades of macula involving retinal detachment (MIRD) based on the morphological extent of involvement using the <t>ETDRS</t> <t>grid</t> in optical coherence tomography (OCT)
Etdrs Grid Heyex 2 Software, supplied by heidelberg engineering, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/high+contrast+etdrs+printed+charts/pmc08380578-89-6-13?v=heidelberg+engineering
Average 90 stars, based on 1 article reviews
etdrs grid heyex 2 software - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Falkenstein Mikrosysteme GmbH etdrs charts
Patient age and VA at baseline. (A) Patient age at first treatment slightly increased over the years. Patients from 2012 onwards were statistically significantly older compared to 2009 (*p < 0.05, Dunnet’s t-test). (B) Baseline VA did not differ over the years. Horizontal lines show VA inclusion limits for MARINA and ANCHOR clinical trials. Note that only 60.6% of our real life cohort falls into the VA inclusion criteria of these clinical trials. Baseline VA for this analysis was adjusted for differences between decimal and <t>ETDRS</t> measurements based <t>on</t> <t>Falkenstein</t> et al . .
Etdrs Charts, supplied by Falkenstein Mikrosysteme GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/high+contrast+etdrs+printed+charts/pmc06397189-47-12-16?v=Falkenstein+Mikrosysteme+GmbH
Average 90 stars, based on 1 article reviews
etdrs charts - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

86
Precision Vision etdrs
Patient age and VA at baseline. (A) Patient age at first treatment slightly increased over the years. Patients from 2012 onwards were statistically significantly older compared to 2009 (*p < 0.05, Dunnet’s t-test). (B) Baseline VA did not differ over the years. Horizontal lines show VA inclusion limits for MARINA and ANCHOR clinical trials. Note that only 60.6% of our real life cohort falls into the VA inclusion criteria of these clinical trials. Baseline VA for this analysis was adjusted for differences between decimal and <t>ETDRS</t> measurements based <t>on</t> <t>Falkenstein</t> et al . .
Etdrs, supplied by Precision Vision, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/high+contrast+etdrs+printed+charts/10__1097_slash_opx__0000000000002040-68-10-15?v=Precision+Vision
Average 86 stars, based on 1 article reviews
etdrs - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

90
heidelberg engineering etdrs view
Patient age and VA at baseline. (A) Patient age at first treatment slightly increased over the years. Patients from 2012 onwards were statistically significantly older compared to 2009 (*p < 0.05, Dunnet’s t-test). (B) Baseline VA did not differ over the years. Horizontal lines show VA inclusion limits for MARINA and ANCHOR clinical trials. Note that only 60.6% of our real life cohort falls into the VA inclusion criteria of these clinical trials. Baseline VA for this analysis was adjusted for differences between decimal and <t>ETDRS</t> measurements based <t>on</t> <t>Falkenstein</t> et al . .
Etdrs View, supplied by heidelberg engineering, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/high+contrast+etdrs+printed+charts/pm40364081-79-0-14?v=heidelberg+engineering
Average 90 stars, based on 1 article reviews
etdrs view - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

Image Search Results


Prospective validation studies of AI in DR

Journal: Ophthalmology and Therapy

Article Title: Artificial Intelligence for Diabetic Retinopathy Screening Using Color Retinal Photographs: From Development to Deployment

doi: 10.1007/s40123-023-00691-3

Figure Lengend Snippet: Prospective validation studies of AI in DR

Article Snippet: EyeArt v2.1 , Heydon et al. [ ] , NHS DESP, UK , 30,405 , N/A , ETDRS , rDR , 95.7% (94.8–96.5) , 54.0% (53.4–54.5) , N/A , N/A.

Techniques: Biomarker Discovery

Effect of visual field loss on reading ability on ETDRS charts. (A) Microperimetry of the remaining central visual field in one eye with advanced choroideremia. The colored areas indicate the seeing parts of the retina. (B) ETDRS chart for measuring visual acuity. (C) A simulation of the appearance of the chart in B to the eye in A, making it difficult to track across the letters and obtain an accurate measure of visual acuity. (D) E-ETDRS presentation with single letter on the center of the screen. (E) EVA-SL presentation with a single line of letters across the center of the screen. (F) Simulation of visual field loss on EVA, the patient can more easily search around the letter as it stays within a limited area.

Journal: The British journal of ophthalmology

Article Title: Validation of Electronic Visual Acuity (EVA) Measurement Against Standardised ETDRS Charts In Patients With Visual Field Loss From Inherited Retinal Degenerations

doi: 10.1136/bjophthalmol-2019-315124

Figure Lengend Snippet: Effect of visual field loss on reading ability on ETDRS charts. (A) Microperimetry of the remaining central visual field in one eye with advanced choroideremia. The colored areas indicate the seeing parts of the retina. (B) ETDRS chart for measuring visual acuity. (C) A simulation of the appearance of the chart in B to the eye in A, making it difficult to track across the letters and obtain an accurate measure of visual acuity. (D) E-ETDRS presentation with single letter on the center of the screen. (E) EVA-SL presentation with a single line of letters across the center of the screen. (F) Simulation of visual field loss on EVA, the patient can more easily search around the letter as it stays within a limited area.

Article Snippet: Visual acuity was measured twice using ETDRS charts, EVA automated single letter (E-ETDRS) and EVA single line (EVA-SL) presentation (EMMES, USA).

Techniques:

(A) Box and whisker plot showing mean, standard deviation and range of data points in healthy volunteer participants with outliers identified. (B) Bland-Altman plot comparing ETDRS charts and the two EVA presentation paradigms of the automated E-ETDRS and single line presentation (EVA-SL) in healthy volunteer group. The dashed lines represent mean difference and the dotted lines show the limits of agreement. (C) Box and whisker plot showing mean, standard deviation and range of data points in patient participants with outliers identified in the rod-cone dystrophy patient group. (D) Bland-Altman plot comparing ETDRS charts and the E-ETDRS paradigm in the patient group. (E) Bland-Altman plot comparing ETDRS charts and single line presentation (EVA-SL) in the patient group. (F) Bland-Altman plot comparing E-ETDRS and EVA-SL. The dashed lines in the Bland-Altman plots represent mean difference and the dotted lines show the limits of agreement.

Journal: The British journal of ophthalmology

Article Title: Validation of Electronic Visual Acuity (EVA) Measurement Against Standardised ETDRS Charts In Patients With Visual Field Loss From Inherited Retinal Degenerations

doi: 10.1136/bjophthalmol-2019-315124

Figure Lengend Snippet: (A) Box and whisker plot showing mean, standard deviation and range of data points in healthy volunteer participants with outliers identified. (B) Bland-Altman plot comparing ETDRS charts and the two EVA presentation paradigms of the automated E-ETDRS and single line presentation (EVA-SL) in healthy volunteer group. The dashed lines represent mean difference and the dotted lines show the limits of agreement. (C) Box and whisker plot showing mean, standard deviation and range of data points in patient participants with outliers identified in the rod-cone dystrophy patient group. (D) Bland-Altman plot comparing ETDRS charts and the E-ETDRS paradigm in the patient group. (E) Bland-Altman plot comparing ETDRS charts and single line presentation (EVA-SL) in the patient group. (F) Bland-Altman plot comparing E-ETDRS and EVA-SL. The dashed lines in the Bland-Altman plots represent mean difference and the dotted lines show the limits of agreement.

Article Snippet: Visual acuity was measured twice using ETDRS charts, EVA automated single letter (E-ETDRS) and EVA single line (EVA-SL) presentation (EMMES, USA).

Techniques: Whisker Assay, Standard Deviation

A) Test preference of the patient participants after presentation of ETDRS chart and E-ETDRS only; B) test preference after completion of all three tests. Line thickness indicates number of participant responses. For both diagrams, the key represents how many patients contributed to each line based on thickness. C) The reason for test preference after completion of ETDRS Charts and E-ETDRS charts. Reasons were assigned to one of three broad categories, identified by the colored background. D) Test preference after completion of all three tests (ETDRS charts, E-ETDRS and EVA-SL), and reasons given to support test preference. Line thickness indicates number of participant responses. Line colour indicates preferred test. Where more than one reason was given, both are included. Reasons are grouped according to thematic content.

Journal: The British journal of ophthalmology

Article Title: Validation of Electronic Visual Acuity (EVA) Measurement Against Standardised ETDRS Charts In Patients With Visual Field Loss From Inherited Retinal Degenerations

doi: 10.1136/bjophthalmol-2019-315124

Figure Lengend Snippet: A) Test preference of the patient participants after presentation of ETDRS chart and E-ETDRS only; B) test preference after completion of all three tests. Line thickness indicates number of participant responses. For both diagrams, the key represents how many patients contributed to each line based on thickness. C) The reason for test preference after completion of ETDRS Charts and E-ETDRS charts. Reasons were assigned to one of three broad categories, identified by the colored background. D) Test preference after completion of all three tests (ETDRS charts, E-ETDRS and EVA-SL), and reasons given to support test preference. Line thickness indicates number of participant responses. Line colour indicates preferred test. Where more than one reason was given, both are included. Reasons are grouped according to thematic content.

Article Snippet: Visual acuity was measured twice using ETDRS charts, EVA automated single letter (E-ETDRS) and EVA single line (EVA-SL) presentation (EMMES, USA).

Techniques:

Objective grading of various reading charts with a surgical microscope. The reticule centers on the character being used for objective measurement: (A) 20/200 character on the ETDRS chart by Alcon; (B) 20/200 character on the ETDRS chart by Bausch & Lomb; (C) J16 character on the Rosenbaum chart; and (D - E) N24 characters on the alphabetical and numerical N-notation charts, respectively.

Journal: Ophthalmology Science

Article Title: A Comparative Validation Study of Near Visual Acuity Assessment Using Different Handheld Acuity Charts

doi: 10.1016/j.xops.2025.100790

Figure Lengend Snippet: Objective grading of various reading charts with a surgical microscope. The reticule centers on the character being used for objective measurement: (A) 20/200 character on the ETDRS chart by Alcon; (B) 20/200 character on the ETDRS chart by Bausch & Lomb; (C) J16 character on the Rosenbaum chart; and (D - E) N24 characters on the alphabetical and numerical N-notation charts, respectively.

Article Snippet: Four near visual acuity charts were included in this study: the ETDRS chart by Alcon (ETDRS-A, Alcon Inc), the ETDRS chart by Bausch & Lomb (ETDRS-BL, Bausch + Lomb), the Rosenbaum near vision chart (Veatch Ophthalmic Instruments), and the N-notation chart.

Techniques: Microscopy

Bland−Altman plots of N-notation and Rosenbaum charts against ETDRS-A and ETDRS-BL as reference. Various Bland−Altman plots depicting comparisons between (A) ETDRS-BL against ETDRS-A, (B) ETDRS-A against N-notation chart letters, (C) ETDRS-A against N-notation chart numbers, (D) ETDRS-A against Rosenbaum chart numbers, (E) ETDRS-BL against N-notation chart letters, (F) ETDRS-BL against N-notation chart numbers, and (G) ETDRS-BL against Rosenbaum chart numbers. ETDRS-A = ETDRS chart by Alcon; ETDRS-BL = ETDRS chart by Bausch & Lomb; logMAR = logarithm of the minimum angle of resolution.

Journal: Ophthalmology Science

Article Title: A Comparative Validation Study of Near Visual Acuity Assessment Using Different Handheld Acuity Charts

doi: 10.1016/j.xops.2025.100790

Figure Lengend Snippet: Bland−Altman plots of N-notation and Rosenbaum charts against ETDRS-A and ETDRS-BL as reference. Various Bland−Altman plots depicting comparisons between (A) ETDRS-BL against ETDRS-A, (B) ETDRS-A against N-notation chart letters, (C) ETDRS-A against N-notation chart numbers, (D) ETDRS-A against Rosenbaum chart numbers, (E) ETDRS-BL against N-notation chart letters, (F) ETDRS-BL against N-notation chart numbers, and (G) ETDRS-BL against Rosenbaum chart numbers. ETDRS-A = ETDRS chart by Alcon; ETDRS-BL = ETDRS chart by Bausch & Lomb; logMAR = logarithm of the minimum angle of resolution.

Article Snippet: Four near visual acuity charts were included in this study: the ETDRS chart by Alcon (ETDRS-A, Alcon Inc), the ETDRS chart by Bausch & Lomb (ETDRS-BL, Bausch + Lomb), the Rosenbaum near vision chart (Veatch Ophthalmic Instruments), and the N-notation chart.

Techniques:

Illustration for 5 grades of macula involving retinal detachment (MIRD) based on the morphological extent of involvement using the ETDRS grid in optical coherence tomography (OCT)

Journal: Graefe's Archive for Clinical and Experimental Ophthalmology

Article Title: Functional recovery after macula involving retinal detachment and its correlation with preoperative biomarkers in optical coherence tomography

doi: 10.1007/s00417-021-05113-3

Figure Lengend Snippet: Illustration for 5 grades of macula involving retinal detachment (MIRD) based on the morphological extent of involvement using the ETDRS grid in optical coherence tomography (OCT)

Article Snippet: In this study, we used the ETDRS grid provided by Heyex 2 Software (Heidelberg Engineering, Heidelberg, Germany).

Techniques: Tomography

Patient age and VA at baseline. (A) Patient age at first treatment slightly increased over the years. Patients from 2012 onwards were statistically significantly older compared to 2009 (*p < 0.05, Dunnet’s t-test). (B) Baseline VA did not differ over the years. Horizontal lines show VA inclusion limits for MARINA and ANCHOR clinical trials. Note that only 60.6% of our real life cohort falls into the VA inclusion criteria of these clinical trials. Baseline VA for this analysis was adjusted for differences between decimal and ETDRS measurements based on Falkenstein et al . .

Journal: Scientific Reports

Article Title: Anti-VEGF injection frequency correlates with visual acuity outcomes in pro re nata neovascular AMD treatment

doi: 10.1038/s41598-019-38934-8

Figure Lengend Snippet: Patient age and VA at baseline. (A) Patient age at first treatment slightly increased over the years. Patients from 2012 onwards were statistically significantly older compared to 2009 (*p < 0.05, Dunnet’s t-test). (B) Baseline VA did not differ over the years. Horizontal lines show VA inclusion limits for MARINA and ANCHOR clinical trials. Note that only 60.6% of our real life cohort falls into the VA inclusion criteria of these clinical trials. Baseline VA for this analysis was adjusted for differences between decimal and ETDRS measurements based on Falkenstein et al . .

Article Snippet: We have corrected our baseline VA values for comparison with trials using ETDRS charts based on Falkenstein et al . Lines read only partially during decimal VA testing were counted if at least three of five characters were read correctly.

Techniques: Clinical Proteomics